JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Braselton, W.
Right arrow Articles by Herdt, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Braselton, W.
Right arrow Articles by Herdt, T.
Journal of Veterinary Diagnostic Investigation, Vol 9, Issue 4, 395-400
Copyright © 1997 by American Association of Veterinary Laboratory Diagnosticians


Articles

Biopsy mineral analysis by inductively coupled plasma-atomic emission spectroscopy with ultrasonic nebulization

WE Braselton, KJ Stuart, TP Mullaney, and TH Herdt

Animal Health Diagnostic Laboratory, College of Veterinary Medicine, Michigan State University, East Lansing 48824, USA.

Liver copper concentration is generally considered the best measure of copper nutritional status in cattle. Ultrasonic nebulization in conjunction with inductively coupled plasma-atomic emission spectroscopy (ICP-AES) was investigated as a method to provide adequate sensitivity to allow accurate simultaneous measurement of copper and 14 additional elements from needle biopsy samples. The element concentration frequency distribution profile of 12 elements routinely present in liver was compared to profiles of the elements in fat, muscle, vena cava, kidney, and clotted blood. The profiles could be used to confirm the authenticity of the liver biopsy sample. Element concentrations in biopsy samples taken in triplicate from the five lobes of a bovine liver were compared to those from triplicate wedge sections taken adjacent to the biopsies and analyzed by conventional ICP-AES. Precision between biopsies was equal to or better than precision between wedge samples. Some element concentrations determined by the biopsy procedure differed statistically from those determined by the wedge procedure, but differences were not sufficient to influence clinical interpretation of data.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Association of Veterinary Laboratory Diagnosticians, Inc.