JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, H.
Right arrow Articles by Morrison, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, H.
Right arrow Articles by Morrison, R.
Journal of Veterinary Diagnostic Investigation, Vol 3, Issue 4, 283-286
Copyright © 1991 by American Association of Veterinary Laboratory Diagnosticians


Articles

Evaluation of serologic methods for the detection of antibodies to encephalomyocarditis virus in swine fetal thoracic fluids

HS Kim, HS Joo, WT Christianson, and RB Morrison

Department of Clinical and Population Sciences, College of Veterinary Medicine, University of Minnesota, St. Paul 55108.

Hemagglutination inhibition (HI) and agar gel immunodiffusion (AGID) tests were compared to the serum neutralization (SN) test to evaluate their ability to detect antibodies to encephalomyocarditis virus (EMCV). Swine fetal thoracic fluids of known EMCV SN antibody titers (200 samples greater than or equal to 1:2, 100 samples less than 1:2) were selected from a collection of field cases. The thoracic fluids were tested for EMCV antibodies by HI and AGID, and the results were compared to those of the SN test. Of 200 SN antibody-positive samples, 183 (91.5%) and 173 (86.5%) were positive in HI and AGID tests, respectively. Of 100 SN-negative samples, 81 (81%) and 94 (94%) were negative in HI and AGID tests, respectively. Agreement between the tests was analyzed by calculating Kappa values. The values were 0.73 between SN and HI tests and 0.77 between SN and AGID tests, indicating very good to excellent agreement for HI and AGID tests with the SN test. Of 200 SN-positive samples, 19 samples with low SN titers (1:2-1:16) were further tested by Western immunoblotting, and all were confirmed as positive. Interpretation of the present results suggests that both HI and AGID tests can be used as alternatives to the SN test.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Association of Veterinary Laboratory Diagnosticians, Inc.