JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bak, H
Right arrow Articles by Sorensen, V
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bak, H
Right arrow Articles by Sorensen, V
Journal of Veterinary Diagnostic Investigation, Vol 18, Issue 4, 355-361
Copyright © 2006 by American Association of Veterinary Laboratory Diagnosticians


Articles

Control panels of meat juice samples for a Salmonella enzyme-linked immunosorbent assay

H Bak and V Sorensen

Danish Food and Veterinary Research, Bulowsvej 27, 1790 Kobenhavn V, Denmark.

In the Danish pig production system, an indirect enzyme-linked immunosorbent assay (ELISA) for detection of antibodies in meat juice is used for Salmonella surveillance. Quality control (QC) of this ELISA was previously based on repeated testing of control serum samples. The purpose of the study reported here was to collect, characterize, and implement a panel of meat juice pools for supplemental internal QC. Muscle samples for extraction of meat juice were collected from slaughter pigs of 5 herds infected with Salmonella spp. and from 4 herds without Salmonella infection. A QC panel with 39 pools of meat juice, yielding ELISA optical density (OD) values covering the full range of expected OD values, was prepared and tested repeatedly to determine mean and SD OD values. Each pool was tested twice on each microtitration plate, and the results were used to determine limits for validity of future tests. This QC panel was included as an internal QC to be tested every month. Besides the QC panel, 2 panels containing 100 samples of meat juice with OD above the positive cut-off value and 100 samples with OD below that value were prepared for quarterly control of the diagnostic sensitivity (DSe) and the diagnostic specificity (DSp) of the ELISA. The inclusion of these panels in the QC system will provide information about drifts in DSe and DSp of the test. The procedures described here can be applied to other tests where meat juice samples are used for testing.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Association of Veterinary Laboratory Diagnosticians, Inc.