JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cecchinato, M
Right arrow Articles by Naylor, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cecchinato, M
Right arrow Articles by Naylor, C.
Journal of Veterinary Diagnostic Investigation, Vol 16, Issue 6, 582-585
Copyright © 2004 by American Association of Veterinary Laboratory Diagnosticians


Articles

Design, validation, and absolute sensitivity of a novel test for the molecular detection of avian pneumovirus

M Cecchinato, E Catelli, CE Savage, RC Jones, and CJ Naylor

Dipartimento di Sanita Pubblica Veterinaria e Patologia Animale, Facolta di Medicina Veterinaria, Universita di Bologna, Via Tolara di Sopra, 50, 40064 Ozzano Emilia (BO), Italy.

This study describes attempts to increase and measure sensitivity of molecular tests to detect avian pneumovirus (APV). Polymerase chain reaction (PCR) diagnostic tests were designed for the detection of nucleic acid from an A-type APV genome. The objective was selection of PCR oligonucleotide combinations, which would provide the greatest test sensitivity and thereby enable optimal detection when used for later testing of field materials. Relative and absolute test sensitivities could be determined because of laboratory access to known quantities of purified full-length DNA copies of APV genome derived from the same A-type virus. Four new nested PCR tests were designed in the fusion (F) protein (2 tests), small hydrophobic (SH) protein (1 test), and nucleocapsid (N) protein (1 test) genes and compared with an established test in the attachment (G) protein gene. Known amounts of full-length APV genome were serially diluted 10-fold, and these dilutions were used as templates for the different tests. Sensitivities were found to differ between the tests, the most sensitive being the established G test, which proved able to detect 6,000 copies of the G gene. The G test contained predominantly pyrimidine residues at its 3' termini, and because of this, oligonucleotides for the most sensitive F test were modified to incorporate the same residue types at their 3' termini. This was found to increase sensitivity, so that after full 3' pyrimidine substitutions, the F test became able to detect 600 copies of the F gene.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Association of Veterinary Laboratory Diagnosticians, Inc.