JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Quigley, K.
Right arrow Articles by Jackson, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Quigley, K.
Right arrow Articles by Jackson, M.
Journal of Veterinary Diagnostic Investigation, Vol 13, Issue 4, 297-300
Copyright © 2001 by American Association of Veterinary Laboratory Diagnosticians


Clinical Trial

Application of a direct flow cytometric erythrocyte immunofluorescence assay in dogs with immune-mediated hemolytic anemia and comparison to the direct antiglobulin test

KA Quigley, BJ Chelack, DM Haines, and ML Jackson

Department of Veterinary Pathology, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, Canada.

A direct flow cytometric erythrocyte immunofluorescence assay (FC) was developed and compared with the direct antiglobulin test (DAT) for detection of erythrocyte-bound immunoglobulin (IgG and IgM) and complement (C3) in dogs with immune-mediated hemolytic anemia (IMHA). Tests were performed on erythrocytes from 13 healthy nonanemic dogs and from 13 anemic dogs with IMHA. The FC and DAT were negative for erythrocyte-bound immunoglobulin in all healthy dogs. The FC was negative for erythrocyte-bound C3 in 12 healthy dogs and positive in 1 healthy dog, and the DAT was negative for C3 in all healthy dogs. Of the 13 IMHA dogs tested for erythrocyte-bound IgG, 12 were positive using the FC and 7 were positive using the DAT. Sensitivity for the detection of erythrocyte-bound IgG in the 26 dogs was 92% for FC and 53% for DAT. Specificity for detection of erythrocyte bound IgG for FC and DAT was 100%. The addition of IgM and/ or C3 did not increase the sensitivity for FC or DAT. In this group of dogs, the FC provided a more rapid, cost-effective, sensitive, objective method to quantitate erythrocyte-bound immunoglobulin and/or complement compared with the currently used DAT.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Association of Veterinary Laboratory Diagnosticians, Inc.