JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Osorio, F.
Right arrow Articles by Grotelueschen, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Osorio, F.
Right arrow Articles by Grotelueschen, D
Journal of Veterinary Diagnostic Investigation, Vol 1, Issue 3, 210-214
Copyright © 1989 by American Association of Veterinary Laboratory Diagnosticians


Articles

Detection of bovine respiratory syncytial virus using a heterologous antigen-capture enzyme immunoassay

FA Osorio, GA Anderson, J Sanders, and D Grotelueschen

Department of Veterinary Sciences, University of Nebraska-Lincoln 68583-0905.

Based on the marked antigenic similarities that exist between antigens of the human and bovine strains of respiratory syncytial virus (RSV), an enzyme immunoassay (EIA) designed to detect human RSV was used to detect bovine RSV. The commercial test kit (RSV EIA) consists of a solid phase (beads) coated with a capture antiserum prepared against the Long strain of human RSV. The RSV EIA test was compared with the method of inoculation of cell cultures and fluorescent antibody (FA) staining of lung tissue for the detection of bovine RSV. Using a cell culture-propagated stock of strain 375 of bovine RSV, the threshold of sensitivity of the EIA test for the cattle strain of RSV was determined to be less than or equal to 10(2.3) CCID50/ml. In addition, RSV EIA detected the bovine RSV in nasal samples obtained from 3 experimentally inoculated cattle. The RSV EIA exhibited a sensitivity of greater than or equal to 80% during the period that shedding of infectious virus took place. All of the bovine RSV FA-positive lung samples (n = 37) were positive by the RSV EIA. Twenty-six of the remaining 214 bovine RSV FA-negative lung samples were positive by the RSV EIA. The RSV EIA was also used to test 137 nasal swabs obtained from cases of bovine respiratory disease. Of these, 38 tested positive by RSV EIA. All samples that tested positive by EIA were confirmed by blocking assays using hyperimmune serum anti-bovine RSV and a pool of monoclonal antibodies specific for that virus.


This article has been cited by other articles:


Home page
jvdiHome page
B. Quinting, B. Robert, C. Letellier, M. Boxus, P. Kerkhofs, F. Schynts, and A. Collard
Development of a 1-step Enzyme-linked Immunosorbent Assay for the Rapid Diagnosis of Bovine Respiratory Syncytial Virus in Postmortem Specimens
J Vet Diagn Invest, May 1, 2007; 19(3): 238 - 243.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
J.-F. Valarcher, H. Bourhy, J. Gelfi, and F. Schelcher
Evaluation of a Nested Reverse Transcription-PCR Assay Based on the Nucleoprotein Gene for Diagnosis of Spontaneous and Experimental Bovine Respiratory Syncytial Virus Infections
J. Clin. Microbiol., June 1, 1999; 37(6): 1858 - 1862.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the American Association of Veterinary Laboratory Diagnosticians, Inc.